Appendix B: Technical Specifications
SolarEdge Installation Guide MAN-01-00057-2.2
59
SE2200
SE3000
SE3500
SE4000
SE4000-
16A
SE5000
SE6000
Unit
Nominal DC input
Voltage
350
Vdc
Maximum input current
8.5
11.5
13.5
15.5
15.5
19.5
23
Adc
Maximum back-feed
current
0
Adc
Reverse-polarity
protection
Yes
Ground-fault isolation
detection
600 kΩ Sensitivity
Overvoltage category
III
Maximum inverter
efficiency
97.6
%
European weighted
efficiency
97.6
97.6
1
97.5
97.5
97.5
97.4
97.4
%
Night-time power
consumption
<2.5
W
Additional Features
Supported
communication
interfaces
RS485, RS232, Ethernet, ZigBee (optional)
Standards Compliance
Safety
IEC-62103 (EN50178), IEC-62109
Grid connection
standards
VDE-AR-N-4105, VDE 0126-1-1, AS-4777, RD-1663, DK 5940
Emissions
IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12, FCC part15 class B
RoHS
Yes
Installation Specifications
AC output
Cable Gland - diameter 9-16
mm
DC input
1 MC4 pair
2 MC4 pairs
Dimensions (W x L x H)
540 x 315 x 172
540 x 315 x 191
mm
Weight
20.2
21.7
kg
Cooling
Natural Convection
Noise
<50
dBA
Operating temperature
range
2
-20 - +50 (M40 version -40 to + 50)
°C
Operating humidity non
condensing
<95
%
1
97.5 for SE3000 with AC current limit of 16A
2
For inverter power de-rating refer to the application note at http://www.solaredge.com/files/pdfs/se-temperature-
derating-note.pdf

Table of Contents