This is used for parallel strings into different inverter MPPTs.
Press enter and press up or down to change the settings(see Figure 6.21).
Figure 6.21 MPPT Parallel Set
YES=<ENT> NO=<ESC>
MPPTParallel: STOP
6.5.7.6 MPPT Parallel Mode
Selecting RUN will enable parallel strings setup.Both MPPT channels will operate in
parallel.
Selecting STOP disables parallel string setup.Both MPPT channels will operate
separately.
The default setting is STOP (disabled).
This function is for maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
This function is used for fixed input voltage(see Figure 6.22).
Figure 6.22 Cnst. Voltage Set
CV Mode:STOP
Voltage:600V
6.5.7.7 Cnst. Voltage Mode
Selecting RUN will enable fixed input voltage. The inverter will not operate if the input
voltage is lower than the set voltage. Selecting STOP will disable this function.
The default setting is STOP (disabled).
This function is for maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
6. Operation
User Manual