6. Operation
User Manual
36
Solis US version inverters have Seven working modes:
1. NULL
2. Volt-watt
3. Volt-Var
4. Fixed-PF
5. Reac-power
6. Power-PF
7. P-Q Mode
2. Volt-Watt
1.NULL
Description: Inverter is not under any working mode.
Figure 6.24 Volt-Watt characteristic
Description: Inverter will change the active output power based on voltage change.
Note: This is the Volt-Watt Setting for UL1741SB Standards.
P rated
V1 Voltage
P2
V2 VH
Active Power
(Generation)
Active Power
(P1,V1)
(P2,V2)
Setting Parameter
V1
P1
V2
P2
Response time
Default Value
1.06 Un
Prated
1.1 Un
10 s
Range
1.05 Un~1.09 Un
N/A
0.5 s-60 s
0.2 Prated
1.06 Un~1.1 Un
0- Prated
Table 6.5