Sony DCR-TRV7 - GUM PLL Adjustment (CB-58 Board); Original Oscillation Adjustment (CB-58 Board); HALL Adjustment

Sony DCR-TRV7
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5–10
Arbitrary
Pin of IC200 (CL200)
Frequency counter
F
1C
f = 18000000 ± 90Hz (NTSC)
f = 18000000 ± 90Hz (PAL)
Not required
DDS display data of EVF, LCD or
TV monitor (Note 3)
F
1E, 1F
15 to 19 during IRIS OPEN (Note 1)
81 to 85 during IRIS CLOSE (Note 2)
3. GUM PLL Adjustment (CB-58 Board)
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Arbitrary
CL207 (C288 )
Digital voltmeter
F
4D
1.75 ± 0.05 Vdc
Adjusting method:
1) Set data: 01 to page: 6, address: 00.
2) Change the data of page: F, address: 4D, and set the DC voltage
to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Set data: 00 to page: 6, address: 00.
4. Original Oscillation Adjustment (CB-58 Board)
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1) Set data: 01 to page: 6, address: 00.
2) Change the data of page: F, address: 1C, and set the clock
frequency (f) to the specified value.
3) Press the PAUSE button of the adjusting remote commander.
4) Set data: 00 to page: 6, address: 00.
5. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and hall offset.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Set data: 01 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote commander.
Note 2: Set data: 03 to page: 6, address: 01, and press the PAUSE
button of the adjusting remote commander.
Note 3: DDS display data of EVF, LCD or TV monitor.
CA 00 00XX
n Object data
Adjusting method:
1) Set data: 01 to page: 0, address: 01.
2) Set data: 02 to page: D, address: 11, and press the PAUSE button
of the adjusting remote commander.
3) Set data: 01 to page: 6, address: 00.
4) Set data: 03 to page: 6, address: 04.
5) Set data: 03 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
6) Set data: 80 to page: F, address: 1F, and press the PAUSE button
of the adjusting remote commander.
7) Set data: 40 to page: F, address: 1E, and press the PAUSE button
of the adjusting remote commander.
8) Read the DDS display data (the bottom two digits of the display
data at the bottom right of the EVF or the LCD display or the
TV monitor), and this data is named W
2.
9) Set data: 30 to page: F, address: 1E, and press the PAUSE button
of the adjusting remote commander.
10) Read the DDS display data, and this data is named W
1.
11) Set data: 01 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
12) Read the DDS display data, and this data is named K
1.
13) Set data: 40 to page: F, address: 1E, and press the PAUSE button.
14) Read the DDS display data, and this data is named K
2.
15) Convert W
1, W2, K1, K2 to decimal notation, and obtain W1´,
W
2´, K1´, K2´. (Refer to Table 5-4-2. “Hexadecimal notation-
decimal notation conversion table” of “Service mode”.)
16) Calculate X
1´ using the following equations (decimal notation
calculation).
A´ = W2´ + K1´ – W1´ – K .................................... Equation 1
B´ = W1´ – K1´.......................................................... Equation 2
X1´= .......................... Equation 3
17) Convert X1´ to hexadecimal notation, and obtain X1.
(Round off to one decimal place)
18) Set data: X
1 to page: F, address: 1E, and press the PAUSE button
of the adjusting remote commander.
19) Change the data of page: F, address: 1F, and adjust the DDS
display data to “17”.
1728 + (48 x A´) – (16 x B´)