5-8
1-2. INITIALIZATION OF B, C, D, E, F PAGE DATA
1-2-1. INITIALIZATION OF C PAGE DATA
1. Initializing the C Page Data
Note: If the C page data has been initialized, the following adjustments
need to be performed again.
1) Modification of C page data
2) Servo and RF system adjustments
3) Video system adjustments
4) IR transmitter adjustments
Adjusting page C
Adjusting Address 10 to DF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 80, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 80, and check that the data changes to
“1C”.
4) Perform “Modification of C Page Data”.
2. Modification of C Page Data
If the C page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. C Page Table
Note: Fixed data-1 : Initialized data. (Refer to “1. Initializing the C Page
Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of C Page
Data”.)
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
EE
00
EE
00
E0
E0
2A
2A
33
33
25
3E
3E
CA
99
88
E3
A1
8A
2D
52
04
00
00
00
00
00
00
00
00
00
Switching position adj.
Fixed data-1
(Initialized data)
Cap FG duty adj.
T reel FG duty adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL f
0
adj.
APC adj.
LPF f
0
adj.
Fixed data-1
(Initialized data)
S VIDEO OUT Y level adj.
S VIDEO OUT chroma level adj.
S VIDEO OUT chroma level adj.
IR video carrier freq. adj.
IR video deviation adj.
IR audio deviation adj.
Chroma BPF f
0
adj.
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Emergency memory address
EE
00
EE
00
E0
E0
2A
2A
33
33
25
3E
3E
CA
99
88
E3
A1
8A
2D
52
04
00
00
00
00
00
00
00
00
00
Address Remark
Initial value
NTSC PAL