6-28
DSC-F828
1-7. ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-7-1. Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1. Connect Error
Fig. 6-1-69
Symptom USB communication with the set is abnormal.
Cause USB cable is not inserted tightly.
Power supply is not installed correctly.
Communication with SEUS is abnormal.
Remedy Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
Install the power supply correctly.
Start the SEUS and click the [Connect] to
check that the connection state is established.
2. RESET the CAMERA and Try Again
Fig. 6-1-70
Symptom The camera is not ready for adjustment.
Cause Data error exists in the camera.
Remedy Reset the camera.
3. Adjustment Time Out
Fig. 6-1-71
Symptom Adjustment does not finish within the specified
time.
Cause Adjustment conditions are wrong.
Data error exists in the camera.
Remedy Check that the conditions such as a subject
are correct.
Reset the camera.
4. Adjustment NG
Fig. 6-1-72
Symptom The adjusted data does not become the speci-
fied value.
Cause Adjustment conditions are wrong.
Data error exists in the camera.
Remedy Check that the conditions such as a subject
are correct.
Reset the camera.
This part indicates
the adjustment
item in which
an error occurred.
This part indicates
the adjustment
item in which
an error occurred.