6-30
DSC-F828
1-8. INITIALIZATION OF DATA
1. Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note: If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “03”.
4) Click [All] of the ALL SELECT buttons to select all pages.
(Fig. 6-1-78 A)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 8E, address: 00 and set data: 20.
9) Click [Save] on the SEUS screen.
10) Wait for more than 3 sec.
Processing after Completing Initializing
Order Page
Address
Data Procedure
1200029 [Set]
2200129 [Set] (Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click [Connect] on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
Fig. 6-1-78
2. Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1: If the 6E or 6F page data have been initialized, the fol-
lowing adjustment needs to be performed again.
1) Camera system adjustments
Note 2: If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “03”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-78
B)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
9) Click [Save] on the SEUS screen.
10) Wait for more than 3 sec.
Processing after Completing Initializing
Order Page
Address
Data Procedure
1200029 [Set]
2200129 [Set] (Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click [Connect] on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
B
A
03