2-20
DXC-D30 (UC)
DXC-D30P (CE)
MEMORY
The details of check result for the communication between each
EEPROM and microcomputer.
080H: The communication between EEPROM (IC510) of ES and
microcomputer is abnormal.
040H: The communication between EEPROM (IC503) of IF and
microcomputer is abnormal.
020H: The communication between EEPROM (IC1) of TG and
microcomputer is abnormal.
010H: The communication between EEPROM (IC9) of MB and
microcomputer is abnormal.
n: The corresponding display for the data of each EEPROM on the
service menu becomes a blank column, when using the standard
value of microcomputer, because of the EEPROM on the MB board
is abnormal, or when using the backup copy, because of the
EEPROM on the TG, IF and ES boards is abnormal.
. Page 22 Present unit condition indication
This is the communication of the production.
This is not related to service.
COND IND
:
B GAIN
000h
:
IRIS POS
:
KWC
000h
:
R GAIN
7e6h
:
TIS
224h
:
POWER
12.1V
OFF
:
PAGE22(NEXT PREV )
EXIT MENU (YES )
800h