17
HCD-BC150/BC250
(3) Select “5. MIRR time Adjust”.
(4) Select “5. Default set MIRR time”.
(5) Select “3. Threshold”.
(6) Confirm the number. If it is 75, go to next step. If it is any
other value, return to step 4.
(7) Push “Open/Close” key to eject tray.
(8) Insert Test Disc HLX-504 into tray.
(9) Push “Open/Close” key to close tray.
(10) Push “2. DVD MIRR time Check”.
(11) Wait for HEX number to display.
(12) Confirm the number, if XX is 28 ~ 70, proceed with next
step. If no, return to 8.
(13) Push “4. Save to EEPROM”.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] tray close
[0] Return to previous menu
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold: 75
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] tray close
[0] Return to previous menu
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: xx xx
3. Thereshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] tray open [close] tray close
[0] Return to previous menu
(14) Confirm the same values are displayed. If it is not same,
return to step 7.
(15) Push “Open/Close” key to eject tray.
(16) Take out HLX-504 and insert Test Disc YEDS-18 into
tray.
(17) Push “Open/Close” key to close tray.
(18) Push “1. CD MIRR time check”.
(19) Wait for HEX number to display.
(20) Confirm the number, if YY is 5A ~ E8, proceed with next
step. If no, return to 15.
(21) Push “4. Save to EEPROM”.
(22) Confirm the same values are displayed. If it is not the
same, return to step 15.
(23) Push “Open/Close” key to eject tray.
(24) Remove Test Disc YEDS-18 from tray.
(25) Push “Open/Close” key to close tray.
(26) Press “0” to return to the Drive Manual Operation menu.
(27) Press “0” to return to the Remocon Diagnosis Menu.
(28) Press power button to switch OFF set.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
MIRR time adjustment Menu
1. CD MIRR time Check: yy YY
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
MIRR time adjustment Menu
1. CD MIRR time check: YY YY
2. DVD MIRR time check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu