Basic DME Wipe Setting Operations 
 
Vertical center position
b)
 
Rotation on the Y axis (horizontal 
direction) 
Rotation on the X axis (vertical 
direction) 
Timing for video selected on a 
utility bus to appear on the screen 
Luminance of border color 
Adjusting DME wipe pattern parameters 
Of the DME wipe patterns, the following have parameters
 
that can be adjusted. 
 
When Brick (for two channels) is selected
 
(pattern numbers 2801 to 2804, 2811 to 2814) 
 
 
 
 
 
 
 
Horizontal center position 
 
 
a)
 
The horizontal center position of the video pasted on Side V. At –100.00
 
the center is at the left edge of the screen, and at +100.00 the center is at
 
the right edge of the screen. 
b)
 
The vertical center position of the video pasted on Side V. At –100.00 the
 
center is at the bottom edge of the screen, and at +100.00 the center is at
 
the top edge of the screen. 
 
When Frame in-out (for two channels) is selected 
•
 
Pattern numbers 2851 to 2854 
 
Timing for video selected on a 
utility bus to appear on the screen 
 
    •  Pattern numbers 2861 to 2864 
 
   
2  In the <Direction> group, specify the DME wipe
 
direction. 
Normal: Regular direction 
Normal/Reverse: Alternate between regular and
 
reverse for each transition 
Reverse: Opposite direction of normal 
 
To specify the DME wipe direction with a button
 
in the transition control block 
In the transition control block of each switcher bank, press
 
the following direction selection buttons. 
NORM: Normal
 
NORM/REV: Normal/reverse
 
REV: Reverse 
 
 
Modifying the DME wipe pattern edge 
(Edge) 
1 
Open the M/E-1 >DME Wipe >Edge/Direction menu
 
(1164). 
2 
If the selected pattern is in 2-channel mode, in the <Ch
 
Select> group, select the corresponding channel. 
You can select more than one channel at the same
 
time. 
3 
Select the edge type in the <Edge> group. 
Border: Border 
Soft Border: Soft border 
4 
Set the parameters according to the selection in step 3. 
When Border is selected 
 
 
 
 
Setting DME Wipe Modifiers 
 
You can apply various modifiers to the DME wipe pattern:
 
setting the DME wipe direction, pattern position, etc. 
For an overview of modifiers, 
1 
“DME Wipe Pattern
 
Variations and Modifiers” (p. 114). 
 
 
Specifying the DME wipe direction 
(Direction) 
You can specify the DME wipe direction (normal/reverse). 
 
To specify the DME wipe direction in a menu 
1  Open the M/E-1 >DME Wipe >Edge/Direction menu
 
(1164). 
 
 
When Soft Border is selected 
 
Luminance of border color 
Display indications when multiple channels are
 
selected at the same time 
The indications for the parameters show the settings
 
on channel 1. When you adjust the settings, this
 
changes the settings on channel 2 by the same amount.