Tally Generation Settings  375 
 
Chapter
 
22
 
Router
 
Interface
 
and
 
Tally
 
Setup
 
3 
Set the source. 
Source From: Specifies the source start address for
 
the wiring configuration. 
Source Level: Specifies the source level for the wiring
 
configuration. 
 
4 
Press [Execute]. 
The settings are common to the parallel and serial tallies. 
 
 
Making New Tally Generation
 
Settings 
1 
Open the Engineering Setup >Router/Tally >Tally
 
Enable >New menu (7364.1). 
2 
Set the following parameters. 
 
 
 
Changing Wiring Settings 
1 
Open the Engineering Setup >Router/Tally >Wiring 
>Modify menu (7363.2). 
2 
Referring to steps 2 and 3 in “Making New Wiring
 
Settings” 
(
1 
p. 374), change the parameters as
 
required. In this case, however, it is not possible to
 
specify multiple destinations in a single operation, and
 
a single address in “Destination Address” must be
 
specified. 
3 
Press [Execute]. 
 
Deleting Wiring Settings 
1 
In the Engineering Setup >Router/Tally >Wiring
 
menu (7363), select the wiring. 
2 
Press [Delete]. 
 
Sorting Wiring Settings 
In the Engineering Setup >Router/Tally >Wiring menu
 
(7363), press [Sort]. 
The sorting of wiring settings are executed in the following
 
order. 
 
 
 
 
 
a) 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, 8:G4, 9:R5, 10:G5, 11:R6, 
12:G6, 13:R7, 14:G7, 15:R8, and 16:G8 (R is an abbreviation of
 
“Red Tally,” and G of “Green Tally”). 
3 
In the <Tally Enable> group, specify the tally
 
generation mode. 
Enable: Always generate a tally. 
Disable: Never generates a tally. 
Tally Input: Generates a tally from the tally input 
 
    state. 
4 
If you selected [Tally Input] as the tally generation
 
mode in step 3, select either of the following in the 
<Tally Input> group. 
DCU1: Generates tally with reference to signal input
 
to DCU1 port. 
DCU2: Generates tally with reference to signal input
 
to DCU2 port. 
5 
Select the tally input port number. 
 
 
6 
Press [Execute]. 
Destination level order (ascending) 
t 
Destination
 
 
   
address order (ascending) 
t 
Source level order
 
(ascending)
 
 
 
 
Tally Generation Settings 
 
You specify the destination to be the reference for tally
 
generation, and make various settings. 
Modifying Tally Generation 
1 
Open the Engineering Setup >Router/Tally >Tally
 
Enable >Modify menu (7364.2). 
2 
With reference to steps 
2 
to 
5 
in “Making New Tally
 
Generation Settings” 
(
1 
p. 375), change the
 
parameters as required. 
3 
Press [Execute].