Register Operations in the Menus  263 
 
This simultaneously recalls M/E-1 register 11 and P/P
 
register 11, and the [M/E1] and [P/P] region selection
 
buttons light. 
2 
Press the region selection button [MSTR], turning it
 
off. 
3 
Turn on only the button for the region you want to
 
change (here, [M/E1]), and recall the desired register
 
(here, Effect 15). 
This recalls M/E-1 register 15, while on P/P register 11
 
remains selected. 
4 
Press the buttons for the regions you want to save on
 
the master timeline (here, [M/E1] and [P/P]), turning
 
them on. 
5 
Press the region selection button [MSTR], turning it
 
on. 
The alphanumeric display shows the register number
 
last used for master timeline operation. 
6 
Press the [EDIT ENBL] button, turning it on. 
This switches the memory recall section to effect
 
editing mode. 
7 
Press the [STOR] button. 
8 
With the numeric keypad buttons, enter the number of
 
the register in which you want to save the master
 
timeline, and press the [ENTR] button. 
This saves M/E-1 register 15 and P/P register 11 in the
 
master timeline register. 
 
 
Creating and Saving a Master
 
Timeline with the Menu 
1 
Open the Effect >Master Timeline >Store menu
 
(6211). 
The status area shows the master timeline register
 
names, register lock status, register number for each
 
region, and so on. 
2 
If necessary, press one of the following buttons in the
 
status area to change the region display. 
M/E, P/P: Indicates assignment of M/E-1 (ME1), P/P
 
(P/P). 
User: Shows the allocations for User1 (USR1) to
 
User8 (USR8). 
DME: Indicates assignment of DME ch1 (DME1),
 
ch2 (DME2), ch5 (DME5), ch6 (DME6), ch7
 
(DME7), and ch8 (DME8). 
DEV1-8: Indicates assignments for Device1 (DEV1)
 
to Device8 (DEV8). 
DEV9-12: indicates assignments for Device9 (DEV9)
 
to Device12 (DEV12). 
Misc: Indicates assignment for P-Bus (PBUS), GPI
 
(GPI), and Macro (MCRO). 
3 
Select the register in which you want to save the
 
master timeline. 
4 
Press [Edit]. 
The Edit menu (6211.1) appears. 
You can also use the [Master Reg] parameter to select
 
the master timeline register in this menu. 
The status area shows the status of each region in this
 
master timeline. 
5 
Select a region. 
You can select more than one region. 
To select all regions, press [ALL]. To select all
 
switcher-related regions (M/E, P/P, User), press [SWR
 
ALL]. 
6 
Press [Assign], turning it on. 
If the selected register is locked, a confirmation
 
message appears asking whether or not to cancel the
 
operation. Press [OK] to return to the previous menu
 
display without carrying out the registration. 
If the operation is carried out, the region selected in
 
step 5 is registered on the master timeline, and the
 
parameters are now valid. 
7 
Select the number of the effect register. 
 
 
8 
Repeat steps 5 to 7 as required to set all regions and
 
register numbers to be saved on the master timeline. 
9 
In the <Store> group, press [Store]. 
To return to the state before saving the master
 
timeline content 
In the <Store> group, press [Undo]. 
 
 
 
Register Operations in
 
the Menus 
 
Using the Effect menu, you can carry out the following
 
effect register operations.