Chapter
 
3
 
Signal
 
Selection
 
and
 
Transitions
 
 
 
 
 
 
[Non Sync] indicator 
 
 
 
 
 
 
 
 
 
[Sync] indicator 
 
 
 
 
 
 
•
 
Even in a non-sync state, you can carry out auto
 
transitions. If you execute an auto transition by pressing
 
the [AUTO TRANS] button, the indicators show the
 
transition progress in the usual way, but when the
 
transition completes, they once again indicate the non-
 
sync state. 
 
 
Fader Lever Operation in Bus Fixed
 
Mode 
 
Flip-flop mode and bus fixed mode 
The following describes the difference between flip-flop
 
mode and bus fixed mode, taking an M/E bank as an
 
example; the functionality is the same, however, on the
 
PGM/PST bank. 
Normally, when a background transition is carried out on
 
the M/E bank, the signals selected on the A and B rows of
 
the cross-point buttons are interchanged at the end of the
 
transition. That is to say, except during a transition, the
 
background output is always from the background A bus.
 
This is called “flip-flop mode.” 
The alternative is known as “bus fixed mode,” in which
 
there is no bus interchange. In this mode, when the fader
 
lever is at the top of its travel the output from the A bus is
 
always 100%, and when the fader lever is at the bottom of
 
its travel the output from the B bus is 100%. 
In the bus fixed mode there is a fixed relationship between
 
the position of the fader lever and the signal output on
 
background A bus and B bus. Depending on the direction
 
of the transition, the fader lever must therefore always be
 
moved in a particular direction, as shown in the following
 
table. This does not affect an auto transition, which is
 
executed regardless of the fader lever direction. 
 
•
 
When a transition applies to a combination of more than
 
one of the background and keys, then the transition for
 
all of these must be in the same direction complying with
 
the above table. 
•
 
If as a result of an auto transition, for example, the fader
 
lever position does not agree with the signal output, this
 
is a non-sync state 
(
1 
p. 72) and the [Non Sync]
 
indicator will appear. 
 
 
 
Transition Preview 
 
With the preview output of the M/E bank and PGM/PST
 
bank, you can check the effect of a transition in advance.
 
To carry out a transition preview, press the [TRANS
 
PVW] button in the transition control block to enable
 
transition preview mode. 
 
 
Notes 
It is not possible to carry out a transition preview during
 
the following. 
•
 
Transitions in progress 
•
 
Multi-program mode 
•
 
Bus fixed mode 
 
 
 
 
 
 
 
 
 
 
 
 
 
Lit buttons 
 
 
 
 
 
Fader lever 
 
 
 
 
 
 
 
 
Flip-flop mode 
 
 
 
 
 
 
 
Bus fixed mode 
Carrying out a transition preview 
1  In the transition control block of a switcher bank, press
 
the [TRANS PVW] button. 
The [TRANS PVW] button lights green, and the
 
switcher is now in the transition preview mode. At this
 
point, the preview output is the same as the program
 
output before the [TRANS PVW] button was pressed.