Control of VTRs, Extended VTRs, and Disk Recorders  229 
 
Chapter
 
11
 
External
 
Devices
 
GPI Timeline Creation and Editing 
This section describes how to set GPI output ports to be
 
registered at a keyframe point, and how to carry out
 
creation and editing of the GPI timeline. 
For details about keyframe creation and editing
 
operations, 
1 
“Creating and Editing Keyframes”
 
(p. 250).
 
 
 
GPI output port settings 
Set the GPI output port number of the switcher or DCU
 
which outputs GPI pulses at a keyframe point on the GPI
 
timeline. 
Use the following procedure to change the settings. 
1 
Open the Device >GPI Timeline >GPI Timeline menu
 
(5311). 
Two lists appear in the status area. 
The “GPI Output” list on the left shows the relation
 
between ports 1 to 8 for the GPI timeline and the
 
trigger pulse output destination ports. The settings in
 
this list will be saved as keyframe point data. 
The “GPI Port” list on the right is for selecting the GPI
 
trigger pulse output destination. 
2 
Select the GPI timeline port. 
3 
Select the trigger pulse output destination.
 
You can select from 2 (SCU) and 3 (DCU). 
4 
Set the port number. 
The indication for the 3rd parameter changes to reflect
 
selection of SCU or DCU. 
 
a)
 
Switcher GPI output port configured in the Setup menu for control
 
from the control panel. 
 
 
 Notes  
For the output port you have set here, be sure to set the
 
trigger type to “Rising Edge,” “Falling Edge” or “Any
 
Edge.” 
For details, 
1 
“Making Control Panel GPI Output
 
Settings” (p. 338) and 
1 
“Making DCU GPI Output
 
Settings” (p. 368). 
5 
Press [Set]. 
Repeat steps 2 to 5 if setting other GPI timeline ports. 
Test firing the trigger 
Press [Test Fire]. 
This outputs a pulse from the selected output port. 
 
 
Clearing output port settings 
 
To clear the setting for each port 
1 
In the list on the left of the status area, select the GPI
 
output port. 
2 
In the list on the right, select “Off.” 
3 
Press [Set]. 
To clear the settings for all ports 
Press [All Off]. 
 
 
Setting the action for a rewind operation 
On the GPI timeline, when the [REWIND] button in the
 
Flexi Pad is pressed, the action set for the first keyframe is
 
not executed; when the [RUN] button is pressed, then the
 
first keyframe action is executed. 
To execute an action when the [REWIND] button is
 
pressed, it is necessary to set this action (Rewind Action).
 
To carry out this setting, press [Rewind Action] in the
 
Device >GPI Timeline >GPI Timeline menu (5311) to
 
recall the Rewind Action menu (5311.1). In this setting
 
screen, use the same setting method as in the screen for
 
setting an action on the GPI timeline. 
Alternatively, you can select the reverse arrangement,
 
whereby when the [REWIND] button is pressed, this
 
executes the action set for the first keyframe, and when the
 
[RUN] button is pressed the first keyframe action is not
 
executed. In this case, the Rewind Action setting is still
 
valid. 
For details about the setting operation, 
1 
“Setting the
 
First Keyframe When a Rewind is Executed” (p. 341).
 
 
 
 
Control of VTRs,
 
Extended VTRs, and Disk
 
Recorders 
 
In this system, for up to 12 VTRs, disk recorders or
 
Extended VTRs connected to a switcher or DCU, you can
 
carry out the following manual operations and timeline
 
settings. 
•
 
Controlling manually from the device control block 
-
 
VTR, disk recorder or Extended VTR selection 
-
 
Tape and disk transport control