Settings Relating to Keys, Wipes, Frame Memory and Color Correction 
 
Chapter
 
19
 
Switcher
 
Setup
 
Off: Bus fixed mode 
For details, 
1 
“Fader Lever Operation in Bus Fixed
 
Mode” (p. 73).
 
 
 
Enabling or disabling the fade-to-black 
function 
In the <FTB> group of the Engineering Setup >Switcher 
>Transition menu (7334), press the program output name
 
to toggle between On and Off. 
On: Enables fade-to-black. 
Off: Disables fade-to-black. 
Normal: The transition progress is linear, according to
 
the fader lever position (factory default setting). 
Adv Tally Mode: When the fader lever is moved from
 
the end of its travel, the tally is output slightly
 
before the transition starts. 
 
 
 
Settings Relating to Keys,
 
Wipes, Frame Memory
 
and Color Correction 
 
     Notes  
The PGM2 to PGM4 settings are valid in Multi Program
 
mode only. 
 
 
Setting a preset color mix 
1 
Open the Engineering Setup >Switcher >Transition 
>Preset Color Mix menu (7334.1). 
2 
In the <Stroke Mode> group, select whether to carry
 
out a transition in one stroke or two strokes. 
Normal: Carries out a preset color mix with two
 
transition operations. 
Single: Carries out a preset color mix with a single
 
transition operation. 
 
Settings for the Show Key Function 
1 
Open the Engineering Setup >Switcher >Key/Wipe/
 
FM/CCR >Show Key menu (7335.1). 
2 
In the <Show Key Enable> group, press the signal for
 
which “show key” is enabled, turning it on. 
3 
To set the time for which “show key” is held, press
 
[Hold Time]. 
4 
Adjust the following parameter. 
 
 Notes   
In bus fixed mode 
(
1 
p. 355), the setting is fixed to
 
“Single.”
 
3 
In the <Non Drop Key> group, select the key setting
 
for a transition including a key. 
To carry out the transition with the key state
 
maintained, press [Key1] to [Key4], turning them on. 
4 
If each time a transition ends the transition type is to
 
return to the previous setting, press [One Time
 
Enable]. 
 
 
Settings relating to fader lever operations 
To select the way in which the fader lever position and the
 
transition progress are related, use the following
 
procedure. 
1 
Open the Engineering Setup >Switcher >Transition 
>Transition Curve menu (7334.2). 
2 
In the <Fader Curve> group, select the fader lever
 
operation mode. 
 
 
Settings for Key Auto Drop Function 
The “key auto drop” function automatically switches off a
 
particular key when you press a cross-point button in a bus
 
that outputs the background on the particular switcher
 
bank (PGM/PST or M/E-1). 
When the background output bus is in flip-flop mode, this
 
is always the A bus. In bus-fixed mode, it is either the A
 
bus or the B bus depending on the fader lever position
 
(
1 
“Fader Lever Operation in Bus Fixed Mode” (p. 73)). 
1  In the Engineering Setup >Switcher >Key/Wipe/FM/
 
CCR menu (7335), press [Key Auto Drop]. 
The Key Auto Drop menu (7335.2) appears.