Settings for Switcher Configuration 
 
In the Engineering Setup >Switcher >Config menu
 
(7331), press [PGM Config]. 
The PGM Config menu (7331.2) appears. 
The status area shows the background and key 
configuration assigned to the output of each bank. 
Select the output you want to set. 
In the <Bkgd> group, select the background. 
In Multi Program mode, select [Clean] or [Utility1], 
In the <Key Enable> group, select [Enable] or
 
[Disable] for each of the keys. 
Chapter
 
19
 
Switcher
 
Setup
 
 
Notes 
•
 
Only the background DME wipe or key 1 can be enabled
 
at any one time. 
•
 
If background DME wipe is enabled, side flags cannot
 
be used in DME wipes. 
1 
In the Engineering Setup >Switcher >Config menu
 
(7331), select the target (M/E-1 or PGM/PST) bank. 
2 
In the <BKGD DME Wipe/Key1> group, select
 
[BKGD DME Wipe]. 
 
 
Setting User Regions 
 
Setting the key preview configuration 
You can make this setting at any time, regardless of the
 
operation mode. 
1 
In the Engineering Setup >Switcher >Config menu
 
(7331), press [K-PVW Config]. 
The K-PVW Config menu (7331.3) appears. 
The status area shows the key preview configuration
 
for each bank. 
2 
Select the key preview to set. 
3 
In the <Mode> group, select [Video] mode or [Key]
 
mode. 
If you select Key mode, skip to step 5. 
4 
In the <Bkgd> group, select the background. 
In Standard mode or Multi Program mode, select
 
[Clean] or [Utility1], then skip to step 5. 
5 
In the <Key1> to <Key4> groups, select the
 
corresponding key status from the following. 
Link: Follows the key on/off setting. 
On: Key is always on. 
Off: Key is always off. 
This assigns the color backgrounds 1 and 2, AUX1 to 24,
 
and frame memory 1 to 8 for User regions to any of User1
 
to User8. 
 
 
 Notes  
If you change the user region settings, the previously
 
stored snapshot data and keyframe effect data can no
 
longer be used. 
1 
In the Engineering Setup >Switcher >Config menu
 
(7331), press [User1-8 Config]. 
The User1-8 Config menu (7331.4) appears. 
The status area shows the region names and assigned
 
user region numbers. 
2 
Select the region to set. 
3 
In the <User Region Assign> group, select the user
 
region you want to assign. If you do not want to assign
 
a user region, select [No Assign]. 
4 
Repeat steps 2 and 3 as required to make the settings
 
for other regions. 
5 
Press [Execute]. 
6 
Check the message, then press [Yes]. 
 
 
Switching Backgrounds using DME
 
Wipes 
On the MVS-3000 or on the MVS-3000A without an
 
MKS-6570 installed, a setting must be enabled in order to
 
use background DME wipes. 
This setting can be made for each of the M/E-1 and PGM/
 
PST banks. 
Setting the Assignments of DME
 
Channels 
On the MVS-6520/6530/3000A, you can select the DME
 
channels to use on the M/E and PGM/PST banks for
 
processed keys or DME wipes. 
1  In the Engineering Setup >Switcher >Config menu
 
(7331), press [DME Config]. 
The DME Config menu (7331.6) appears.