Maintenance
31
To remove the side skirts, the steps should be followed as the section ‘Skirt
Maintenance’.
3. Hold the brush/pad driver with hand and apply downward force to make it drop off as
shown in FIG.29.
FIG.29
4. Clean any debris buildup from hub connection area.
5. Replace the pads when they no longer clean effectively. Replace the brushes when they
no longer clean effectively or the bristles have worn down to the yellow indicator as
shown in FIG.30.
FIG.30
Note: Replace brushes or pads in sets, or it can’t clean the floor effectively.
6. Install the brushes or pads into the scrub head. The brush and scrub head are connected
magnetically. If they cannot align during installation, gently rotate the brush until it enters
the slot.
7. Reinstall the side skirts. Make sure they are securely in place before resuming the
operation of the machine.
Solution Tank Maintenance
The solution tank is recommended to be cleaned monthly to remove scale build-up caused by
the solution.
For safety: Before maintaining or leaving the machine, stop on the level ground and turn off
the machine.
1. Move the machine to a location where water can be drained.
2. Drain solution tank using the solution tank level/drain hose.
3. Rinse the solution tank with clean water.
1) Open the recovery tank top lid
2) Open the solution tank cap as shown in FIG.31.
3) Rinse the solution tank