Maintenance
35
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Machine can’t be
turned on by the
key switch
Load-break switch in the OFF
position
Turn the load-break switch to
ON position
The battery enters a dormant state
Use the charger to activate the
battery
Battery is out of power
Charge the battery using a
charger to activate it
Battery failure.
Contact local dealer or
CenoBots for technical support
Key switch failure
Contact local dealer or
CenoBots for technical support
Control board failure
Contact local dealer or
CenoBots for technical support
Initialization
failure
Choose a wrong map
Choose the right map
Significant changes in the
surrounding environment or being
surrounded by the crowd during
initialization
Move the machine and leave
the crowd
Machine is outside the map areas
Move the machine to the map
areas
The machine
doesn’t execute
the tasks
The battery is too low
Charge the battery
Emergency stop button is pressed
Release the emergency stop
button
Machine is in the manual mode
Switch to the auto mode
Machine stopped
moving
Machine error
Check the detail of the error on
the screen or the mobile app
and follow the steps according
to the guide
Battery is out of power
Charge the battery
The emergency stop is pressed
Release the emergency stop
Machine is switched to the manual
mode
Switch to the auto mode
The machine
can’t be charged
The switch of docking station is
turned to the OFF position
Turn the switch to the ON
position
The air circuit breaker of the
docking is turned to ‘OFF’ position
Turn the air circuit breaker to
the ONposition
The docking station has been
moved
Move the charging station to
the original position
The docking station or charger
didn't get connected to the AC
power
Connect the cord to the outlet