CABLE GUIDE & DROPPER POST STOPPER - CARBON FRAME
# PART NAME PART NUMBER QTY SPEC TOOL
TORQUE
COMMENT
Nm in-lbf
A ICR Guide Bolt
S216500004
1 M4 x 12 mm x 0.7 mm P 2.5 mm hex 4 35.5
B ICR Motor Housing Guide 1 N/A N/A N/A
C Washers 2 M4 mm x 4.2 mm ID x 7 mm OD x 0.8 mm THK N/A N/A N/A
D Seatpost Limiter
S219900041
1 N/A N/A N/A
E Seatpost Limiter Screw
1 Countersunk M4 x 14 mm Self tapping Screw 3 mm hex N/A N/A The stopper is used to stop contact between the dropper post and the motor (do not overtighten)
MOTOR HOUSING CABLE GUIDE ASSEMBLY
1: Place the ICR Guide against the frame with the holes aligned with the frame holes.
2: Insert the screws then torque to spec.
DROPPER STOPPER ASSEMBLY
1: Insert the expanding plug into the frame.
2: Insert the screw and tighten untill the plug is firmly seated in the frame. DO NOT overtighten as this could strip the plastic insert.