Input #1 [Loc]
Pumps: A _ _ _
IF Sensor: DRY
THEN Pump: ON
B:Settings
Mode: ON
Rate: 100 ml/m
Input #1 uses the Master’s
sensor and attaches Pump A to
it. When the sensor is dry, the
pump will turn on.
Pump B is set to run
continuously at 100 ml/min.
Some Examples Using the LM4:
C:Settings
Mode: DOSE
Each: 100 ml
Every: 10 mins
Pump C is set to DOSE 100 ml
every 10 minutes.