Wave User Guide
44
© 2017 Stenograph
3. The Keyboard Hardware Type screen displays.
Keyboard at rest with the deepest depth of stroke setting.
The line of white bars at the top of the screen represents the bottom of the keyboard. The horizontal
position of the line varies depending on the depth of stroke setting. For example, a deeper depth of
stroke places the line closer to the top of the screen. Each individual bar indicates the point the key must
reach or move slightly past in order to register as a stroke. The number below each key is the current
setting. Zero is the factory default.
4. Press and release the key you want to adjust. The gray vertical bar highlights the key selected for
adjustment.
5. Perform one of the following adjustments:
• More—Increase the key sensitivity when the key is not showing in the steno notes and you want
it to register. Increase the sensitivity using increments of 5. It is strongly
recommended that you
make the first incremental setting and assess the change. Turn on CNN or the equivalent and
write against the broadcast for 20 - 30 minutes.
• Less—Decrease the key sensitivity when the key is showing in the steno notes and is not
wanted. Decrease the sensitivity using increments of 10-15. It is strongly
recommended that you
make the first incremental setting and assess the change. Turn on CNN or the equivalent and
write against the broadcast for 20 - 30 minutes.
• Reset—Return all the key settings to the factory default.
6. When finished, press Done.