Select the lane to configure. The lanes selected in installation setup are in white, unused lanes
are grayed out. When a lane is selected in Advanced parameters it is written in blue.
Select / Change the cable length between the antenna and the reader.
Adjust the power of each antenna (from 10% to 100%) to adjust the reading distances.
Adjust the timing for a scan (reading) by step of 1 second (max 30s).
This setting is taking into account only if Input type selection is set to Activating all lanes or
Activating the event lane.
The EPC filter is not available in Secure Mode.
Enter the value for EPC Mask, max 62 hexadecimal bytes.
Adjust the value for offset EPC mask in bytes (0 to 61). It depends on the EPC Mask length.
Filter inversion
not selected: only tags with an EPC value corresponding to the EPC mask value
will be provided to the user.
Filter inversion selected: only tags with an EPC value different from the EPC mask value will be
provided to the user.
RSSI (Received Signal Strength Indication) is a measure of the power in reception of the tag
response. The value returned by the reader is proportional to the amplitude of the reception
signal
Adjust the RSSI value (-110dBm to 0dBm). 0dBm deactivates the RSSI filter.
Filter inversion
not selected: only tags with an RSSI greater than or equal to the specified value
will be provided to the user.
Filter inversion
selected: only tags with an RSSI smaller or equal to the specified value will be
provided to the user.
Ex: RSSI filter = -49f=dBm + Reversal not selected
A tag that will have a RSSI value of -20dBm will be sent back,
A tag that will have a RSSI value of -60dBm will not be sent back.
Scan time, EPC filter and RRSI filter settings are the same for antennas on the same lane. The
cable length and RF power antenna are set for each antenna.