© STid – MU_ULTRYS_V3.0.1_EN
Name
Configuration name: enter the name of the configuration Mobile ID.
The name must be a maximum of 14 characters.
The configuration name "Conf Mobile ID" is reserved for the STid Mobile ID
®
configuration.
Reading mode
Reader configured to read UHF identifiers or Bluetooth® identifiers.
Feedback of all identifier.
Reading the UHF identifier triggers reading of the Bluetooth
®
identifier.
The reader scans in UHF. As soon as a valid UHF identifier is detected (key,
EPC filter, etc.), the reader checks (for a timeout of 6s by default) whether a
Bluetooth® identifier has to be returned (valid VCard read).
Timeout adjustable at Step 7:
The reader returns the two identifiers one after the other.
If beyond the scan time no valid Bluetooth® identifier is read, the reader
resumes UHF scan.
Reading the Bluetooth
®
identifier triggers reading of the UHF identifier.
The reader scans in Bluetooth
®
. As soon as a valid VCard is detected (Site code,
etc.), the reader checks (for a timeout of 6s by default) whether a UHF
identifier has to be returned (key, EPC filter…).
Timeout adjustable at Step 7:
The reader returns the two identifiers one after the other.
If beyond the scan time no valid UHF identifier is read, the reader resumes
Bluetooth
®
scan.