OPERATION
Maintenance and care
www.stiebel-eltron.com WPF basic | 17
4.6 Remote control FE7
PIC00000609
With the FE7 remote control, the following options are available:
- changing the set room temperature for heating for heating
circuit 1 or 2 by ± 5 °C.
- changing the operating mode.
It offers the following controls:
- one rotary selector for changing the set room temperature
- one rotary selector with the following positions
-
Automatic mode
-
Constant setback mode
-
Constant day mode
Note
The remote control is only active when the WPMiw is in
automatic mode.
4.7 Remote control FEK
Note
In cooling mode, the WPF requires the FEK for area cool-
ing systems, e.g. underfloor heating systems, chilled
ceilings, etc. Apart from the room temperature, it also
determines the dew point temperature to prevent con-
densation.
PIC00000704
With the FEK remote control, the following options are available:
- changing the set room temperature for heating for heating
circuit 1 or 2 by ± 5 °C.
- changing the operating mode.
It offers the following controls:
- one rotary selector for changing the set room temperature
- one “Away” button
- one “Info” button
- one key to select the following operating modes:
-
Standby mode
-
Automatic mode
-
Constant day mode
-
Constant setback mode
Note
The parameters heating curve, room temperature and
heating program are not shown at the WPMiw heat pump
manager if the FEK is pre-selected for a specific heating
circuit.
5. Maintenance and care
!
Appliance and system damage
Maintenance work, such as checking the electrical safety,
must only be carried out by a qualified contractor.
A damp cloth is sufficient for cleaning all plastic and sheet steel
parts. Never use abrasive or corrosive cleaning agents.
Protect the appliance from dust and dirt ingress during building
work.
We recommend a regular inspection (to establish the current con-
dition of the system), and maintenance by a qualified contractor if
required (to return the system to its original condition).
6. Troubleshooting
Fault Cause Remedy
There is no hot water or
the heating system stays
cold.
The fuse/MCB has blown/
has responded.
Check the fuse/MCB in
your fuse box/distribu-
tion panel.
6.1 Other problems
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate. The type plate is located on the front
at the top on the right or left hand side of the casing.
Sample type plate
Montageanweisung beachten! Dichtheit geprüft!
Made in Germany
*xxxxxxxxxxxxxxxxxx*
26�03�01�1736
1
1 Number on the type plate