INSTALLATION
Mounting
www.stiebel-eltron.com WPF basic | 25
10.12.1 Electrical connection WPF basic (three-phase)
Connection X3: Heat pump, electric booster heater and brine
pump
L1 L2 L3 N L1 L2 L3 L1’ L2’ L3’
L1 L2 L3 N L1 L2 L3 L1’ L2’ L3’
ON
KS
Kühlen
1 2 3 4 5 6 7 8 9 10 11 12 13
B1
B1
26�03�01�1579
Heat pump power supply (compressor)
L1, L2, L3, PE
DHC power supply (electric booster heater)
L1, L2, L3, N, PE
Connected load Terminal assignment
2.6 kW L1 N PE
3.0 kW L2 N PE
3.2 kW L3 N PE
5.6 kW L1 L2 N PE
5.8 kW L1 L3 N PE
6.2 kW L2 L3 N PE
8.8 kW L1 L2 L3 N PE
Three-phase brine pump power supply
L1', L2', L3', PE
Single phase brine pump power supply
L1', N (X3/4) PE
!
Material losses
When a single phase brine pump is connected, protect
the heat pump and the DHC only via one common RCD.
If no electric emergency/booster heater is connected, N
must be tapped from X25 for the brine pump.
After connecting all electrical cables, refit and seal the cover over
the mains terminal strip.
Connections X4: Control unit
D0000076045
Mains supply: L, N, PE
Outputs:
ON Compressor signal
KS Brine pump signal
Cooling Cooling mode
MKP Mixer circuit pump and N, PE
M(A) Mixer open
M(Z) Mixer closed
HKP Heating circuit pump and N, PE
F8 Brine pressure switch
Control inputs:
EVU Power supply utility enable signal
!
Material losses
Only connect energy efficient circulation pumps ap-
proved by us.
When using energy efficient circulation pumps not ap-
proved by us, an external relay with a breaking capacity
of at least 10A/250VAC or our relay set WPM-RBS is
required.
Part no.:
UP 25/7.0 E 232942
UP 25/7.5 E 232943
UP 25/7.5 PCV 235949
UP 30/7.5 E 233947
WPKI-HK E 233602
WPKI-HKM E 233603