Emergency messages
Operation manual
ID 441896.05
WE KEEP THINGS MOVING
39
8
7110
hex
: brake chopper 8: temperature 42: Temperature brake resistor
9000
hex
: external error 1: generic error 44: External fault 1
4380
hex
: temperature drive I2t 8: temperature 45: Overtemperature motor i2t
3120
hex
: mains undervoltage 4: voltage 46: Low voltage
8311
hex
: excess torque 1: generic error 47: Torque limit
8100
hex
: communication 10: communication 52: Communication
5200
hex
: device hw control 1: generic error 55: Option board
8400
hex
: Velocity speed control 1: generic error 56: Overspeed
6100
hex
: internal software 1: generic error 57: Second activation
2110
hex
: short circuit earth 2: current 58: Grounded
4280
hex
: temperature device I2t 8: temperature 59: Overtemperature device i2t
6200
hex
: user software 1: generic error 60 - 67: Application event 0 to 7
9000
hex
: external error 1: generic error 68: External fault 2
7120
hex
: motor 1: generic error 69: Motor connection
6300
hex
: data record 1: generic error 70: Parameter consistency
7110
hex
: brake chopper 1: generic error 72: Brake test timeout
7110
hex
: brake chopper 1: generic error 73: Axis 2 brake test timeout
7110
hex
: brake chopper 1: generic error 74: Axis 3 brake test timeout
7110
hex
: brake chopper 1: generic error 75: Axis 4 brake test timeout
Error Code
Hex value: Designation
Error Register