POSITool over EtherCAT
Operation manual
ID 441896.05
WE KEEP THINGS MOVING
91
12
12.5 Principle of operation
EtherCAT makes possible:
The cyclic transfer of process data (PDO) using a controller or CNC
Acyclic services for writing and reading parameters in the inverter using CoE
(SDO) as well as the transfer of manufacturer-specific protocols (VoE,
Vendor-specific protocol over EtherCAT).
Using the VoE technology it is possible to establish communication between
POSITool on the PC with the EtherCAT master and devices in the 5
th
generation
of STÖBER inverters. Using this communication link, you can undertake all the
usual actions such as configuration download, configuration upload, diagnostics
and commissioning. In this situation the EtherCAT master represents the gateway
via which communication is established.
Fig. 12-6 EtherCAT master and POSITool
Driver software is included in POSITool for communication with the inverters; on
sending data this driver packs the inverter messages into the so-called Vendor-
specific protocol over EtherCAT. The VoE messages are sent via UDP/IP to the
mailbox gateway in the TwinCAT
®
software. The mailbox gateway forwards the
VoE messages via the EtherCAT master to the related inverters. The inverters
reply with VoE messages to the EtherCAT master. There the mailbox gateway
receives the reply messages and sends them back to POSITool. For this method
of communication to function, POSITool must know both the IP address of the
mailbox gateway and the address of the required inverters in the EtherCAT
system.