Stonex S980A GNSS Receiver – User Manual v1.0
38
8.1.2 Initialization
After the activation of the sensor, go in Survey mode.
If the sensor is not ready to work yet, Cube-a will show you which operations
are necessary to perform its initialization.
There is a necessary pre-requisite to use the IMU: the status of the GNSS
solution must be Fixed (Fixed, aRTK Fixed, Surefixed or ExtraSafe Fixed).
When, and only when, the receiver is in Fixed, and if the sensor needs to
be initialized, two different screens could show up.
The first screen pops up seldomly: it lets the sensor adjust for the local
magnetic field. Just rotate the pole with the device as shown in the picture
below.
The second screen lets the sensor adjust the calibration parameters based on
the local GNSS position and accuracy.