Objet Desktop 3-D Printer Site Preparation Guide
DOC-04002 13 Rev. D2
5 Facility Requirements
5.1 Electrical Power Requirements
Yourprinterhasthefollowingelectricalrequirements.
5.1.1 Power
ATypeCcircuitbreakerwiththefollowingspecificationisrecommended
ontheprinter’spowerline,subjecttothelocalelectricalcode.
Asta
bleanduninterruptedpowersupplyisrequired.Thepowertothe
systemshouldbesupplieddirectlyfromthemainel
ectricalpanel,without
anytappedfeedsontheline.
5.1.2 Grounding
Theprinterisgroundedthroughasingle‐phaseACplug.Makesurethat
thegroundconnectioninthewalloutletisproperlygrounded,in
accordancewiththelocalelectricalsafetycodes.
5.1.3 Main Power Connectors
Theprinterisshippedwithoutapowercable.Thepowercableissupplied
byyourlocalStratasysdealer.
Voltage Current
100–120 VAC single-phase, 50–60 Hz 7 A
200–240 VAC single-phase, 50–60 Hz 3.5 A
Table 3: Printer power rating
Voltage Circuit Breaker
100–120 VAC 10 A
200–240 VAC 6 A
Table 4: Circuit breaker requirements