Repairs - fuses
Type 3:
Battery fuse: type 3
70 A fuse = strip fuse -
Fuse holder at the plus pole
of the batteries (illustration
without insulating cap)
To replace Fuse:
Remove insulating cap of the fuse
holder.
Fire and burn hazard by
bridging the Battery Poles!
Do remove insulator of fuse holder only.
Loosen both clamping screws
(1, SW 4 mm) of the strip fuse.
Replace fuse strips (2) and tighten
claming screws.
Place insulating cap of fuse holder.