SUMAVISION EMR Operation Introduction
21 /53
Fig. 5-1 Multiplexing Screen of WEB Network Management
Step 1: Click “Multiplexing Setting” on the network management screen to navigate to the
multiplexing screen;
Step 2: Select an input board card;
Step 3: Select a program to be multiplexed;
Step 4: Select an output board card for multiplexing;
Step 5: Click a destination output port for multiplexing;
Step 6: Click “Multiplex” button;
Step 7: Click “Set” to make the multiplexing relationship valid.
5.1.2.3 Output Interface
Select different output interfaces to achieve diversified output streams of the platform.
According to the board card inserted, the platform can select ASI output, IP output or RF
output. The following describes the operating methods for board card output.
ASI output: Insert ASI 4-channel output card (Refer to ASI 4-channel output card)
into the platform to provide ASI output for the platform;
IP output: the platform itself has a main contol gigabit card for IP output (for the
method of setting, refer to Steps for Network Port Output Setting);