9-5
9.Troubleshooting|Error message list
9. Troubleshooting
Error message Possible cause Troubleshooting Refer to
The splicer failed
to align the left
(right) fiber. ▸Con-
tinued to the next
page.
There is dust on the fiber.
Cleave the left (right) fiber again.
▸Instruction
manual that
came with
the cleaver
you use.
▸Continued from
the previous page.
The splicer failed
to align the left
(right) fiber.
There is a foreign object in
the screen.
Clean the microscope lens protection
glass and LEDs.
▸P.3-2
Cleaning LEDs,
P.3-3 Cleaning
lens protection
glass
There is dust on the V-
groove and bare fiber pad.
Clean the V-groove and bare fiber
pad.
▸P.3-1
Cleaning V-
grooves, P.3-2
Cleaning bare
fiber pads
The splicer failed
to inspect the right
and left fibers.
▸Continued to the
next page.
There is dust on the V-
groove and bare fiber pad.
Clean the V-groove and bare fiber
pad.
▸P.3-1
Cleaning V-
grooves, P.3-2
Cleaning bare
fiber pads
OK
Dust