PRINCIPLES OF OPERATION
In a single series of operations, the machine permits recovering and recycling refrigerant fluids
(R134a or R1234yf, depending on machine model) with no risk of releasing the fluids into the
environment, and also permits purging the A/C system of humidity and deposits contained in
the oil.
The machine is in fact equipped with a built-in evaporator/separator that removes oil and other
impurities from the refrigerant fluid recovered from the A/C system and collects them in a
container for that purpose.
The fluid is then filtered and returned perfectly recycled to the bottle installed on the machine.
The machine also permits running certain operational and seal tests on the A/C system.