CUSTOM PROCEDURE
CUSTOM PROCEDURE is a programmable procedure similar to the automatic procedure but
much faster (about 30 minutes of total running time).
From the MAIN MENU:
Select the CUSTOM PROCEDURE, the following screen is displayed (only if the hardware for
hybrid vehicles is installed in the machine):
Select the STANDARD VEHICLE or HYBRID VEHICLE; the following screen will be displayed:
NOTE: When HYBRID VEHICLE is selected UV is disabled.
NOTE: VACUUM TIME and LEACK CHECK have fixed value (not modifiable)
Use arrows to scroll through menu items, then use the keypad to modify procedure
parameters; press OK to begin the CUSTOM PROCEDURE.
From this point onwards refer to automatic procedure paragraph.
AUTOMATIC
MANUAL CUSTOM
SETUP
MAINTENANCE DATA
Hybrid Vehicle
Standard Vehicle
The use of PAG OIL or DYE
in hybrid cars is dangerous
for the safety of the operator.
Please use the
recommended oil with
specific device
R134a CUSTOM PROCEDURE
R134a CUSTOM PROCEDURE
LEAK CHEC
K
1 min
VACUUM TIME 8 min
U
V
GAS FILLING
HP
LP
HP+LP
OIL

Table of Contents