INSTRUCTIONS MANUAL
-47-
Oil will be injected, then if previously selected the UV will be injected :
The machine will continue the refilling with the preset quantity of refrigerant.
Then the following screen will be displayed:
Unscrew HP and LP coupling without disconnect from A/C system end press OK to continue:
A pop-up message is displayed asking confirmation, press YES to continue:
The machine will recover the residual refrigerant into the service hoses, then the following
screen will be displayed:
Are you sure that you have unscrewed
the coupling without removing it?
YES NO
GAS FILLING
R134a MANUAL PROCEDURE
UV Inj.
R134a MANUAL PROCEDURE
UV INJECTION
Recovered gas
Bottle Pressure
A
/C pressure
Bottle temperature
R134a MANUAL PROCEDURE
GAS FILLING
Unscrew HP and LP coupling Without disconnect from A/C
system and press OK
R134a MANUAL PROCEDURE
GAS FILLING
R134a MANUAL PROCEDURE
EMPTYING HOSES
Recovered gas
Hoses pressure