INSTRUCTIONS MANUAL
-91-
Close the liquid valve of the external bottle and press OK, the machine will recover the residual
refrigerant from the hoses, then will display the following screen:
Close and disconnect LP coupling from external bottle and press OK.
Bottle filling procedure successfully completed. Switch the machine off.
NOTE: if the external bottle is not supplied with a liquid side coupling, upend it to recover liquid
refrigerant.
R134a MAINTENANCE
BOTTLE FILLING
Close and disconnect LP or HP coupling from
external bottle and press OK
2 valve bottle
1 valve bottle
R134a MAINTENANCE
BOTTLE FILLING
BOTTLE FILLING – OPERATION COMPLETED
Press OK