Chapter 5 FC Module FRUs 5-23
c. Click View → View Server.
d. Double-click on the server which had the JBOD connected to it. Click the Probe
button.
The JBOD connections are removed now.
e. Click Array Administration → Controller Assignment.
The Assign Server to Manage a RAID Controller window is displayed.
f. Check that the RAID array serial number recorded in Step 15 is displayed.
If the serial number is not displayed, check the operating system information in
the Sun StorEdge 3510 and 3511 FC Array Installation, Operation and Service Manual
and your operating system documentation to complete the configuration. You
will need to stop and restart the Sun StorEdge Configuration Service agent and
console to see the revised configuration.
g. Select a server from the “Server to manage this controller” list and click Apply.
This enables the selected server to manage an array controller. It also disables all
other servers listed from managing the same array.
h. To provide monitoring of other JBODs, click View → Agent Options
Management, and check the box labeled Enable JBOD support.
Your initial configuration of the RAID array is now complete. Refer to the Sun
StorEdge Configuration Service User’s Guide for additional information.
17. If you are creating a dual-controller RAID array, perform the following steps with
the firmware application, to ensure compatibility.
a. To check the controller firmware version of each module, perform these steps:
Remove one I/O controller module so that only one I/O controller module
remains in the array.
Maintain a serial port connection to a terminal or workstation as described in
Step 12.
In the firmware application, choose “view system Information” and record the
Firmware Version.
Insert the second I/O controller module, remove the first module, and choose
“view system Information” to record the Firmware Version of the second module.