Chapter 4: AMI BIOS
4-51
AC Loadline
AC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Valid range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.
DC Loadline
DC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Valid range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.
PS Current Threshold1
The PS Current Threshold1 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 80 for 20A.
PS Current Threshold2
The PS Current Threshold2 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 20 for 5A.
PS Current Threshold3
The PS Current Threshold2 is dened in 1/4A (Amperes) increments
and uses the BIOS mailbox command 0x3. A value of 400 equals 100A.
Valid range is 0-512 which translates to 0-128A. Enter 0 for AUTO.
Default is 4 for 5A.
PS3 Enable
Enable or Disables PS3. Uses BIOS VR mailbox command line 0x3.
The options are Disabled and Enabled.
PS4 Enable
Use this feature to enable or disable PS4. This feature uses BIOS VR
mailbox command line 0x3. The options are Disabled and Enabled.
IMON Slope
IMON (Load Current Monitor) Slope is dened in 1/100 increments and
uses the BIOS VR mailbox command 0x4. Valid range is 0-200. For
example, enter 125 for a 1.25 slope. Enter 0 for AUTO.