Equipment details
105
2. When OF is displayed, adjust the
temperature displacement with +/On or -/
Off (+/-5°C in intervals of 0.5°C).
3. Press Store to leave the OFFSET function.
PUMP 12V/PUMP AU.
The12V pump is used in the PU 12 setting even
if 230V is connected. In the PU AU position,
the 230V pump works, and when 230V is
disconnected, the 12V pump starts. The PU AU
function is activated in the factory setting.
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, step with the arrow
key until PU AU is displayed. Press +/On
and PU 12 is displayed.
3. Press -/Off and PU AU is displayed. Press
Store to leave the pump function.
SERVICE
With this function one can see what values*
from the heater are displayed. The values are
updated once per second.
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, step with the arrow
key until SE is displayed. Press +/On to see
the various values (-/Off can also be used).
3. To leave Service, press Store.
* The values shown during service are:
FA (revolutions): The speed of the fan divided
by 2.
SH (temp): Warm water temperature.
HE (temp): Operating temperature.
OH: If the overheating protection has been
tripped On or alternatively Off.
HS (X): Software version in the heater.
PS (X): Software version on the panel.
I: Amp. Guideline value shown in steps of 0.5 A.
WI: Window breaker on-off.
ES: External start on-off.
10-RS: Heater information, only for ALDE.
BUTTON SOUND
With this function you can connect or
disconnect the button sound to the buttons.
The button sound is disconnected in the factory
setting.