Equipment details
106
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, step with the arrow
key until Sn is displayed. Press +/On and
the button sound is connected.
3. Press -/Off to disconnect the button sound.
Then press Store to leave the button sound
function.
CONSTANT PUMP OPERATION
With this function, selected pump is in constant
operation. The function is disconnected in
the factory setting. This function limits the hot
water supply, particularly when there is little
need of heat.
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, step with the arrow
key until PE is displayed. Press +/On and
constant pump operation is connected.
3. Press -/Off to disconnect constant pump
operation. Then press Store to leave the pump
operation function.
AUTOMATIC TEMP. INCREASE
At 02.00 hours (night time) the boiler starts and
works in accordance with Warm water (item
5) if the clock is set. The reason for this is to
reduce the risk of legionella.
The function is disconnected in the
factory setting.
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, step with the arrow
key until LE is displayed. Press +/On and
legionella is connected.
3. Press -/Off to disconnect legionella. Then
press Store to leave the legionella function.
18. FAULT MESSAGES
When a fault occurs in the system the reason is
shown in the display.
LOW BAT: If the vehicle has a battery voltage
of less than 10.5V, the heater stops. The heater
is automatically reset when the voltage comes
up to 11V.
FAN: Faulty fan speed. Automatic resetting
after 5 minutes.
GAS OUT: Gas finished. Resetting by switching
off and restarting the boiler in accordance with
item 1.
OHEAT 1: Overheating protection tripped. To
re-set, disconnect 12V from the boiler and
connect again.