maintenance/
troubleshooting
43
Synrad Firestar ti-Series operator’s manual
Caution
possible
equipment
damage
Because of their smaller beam diameter, Firestar lasers have signifi-
cantly higher power densities than previous SYNRAD lasers. This
means that even a small amount of contamination on the laser’s out-
put window (or on any optic in the beam path) can absorb enough
energy to damage the optic. Inspect the output window and other
beam delivery optics periodically for signs of contaminants and care-
fully clean as required. In dirty environments, purge laser optics using
filtered air or nitrogen to prevent vapor and debris from accumulating
on optical surfaces.
Danger
serious
personal
injury
Ensure that DC power to the laser is turned off and locked out before
inspecting optical components in the beam path. Invisible CO
2
laser
radiation is emitted through the aperture. Corneal damage or blind-
ness may result from exposure to laser radiation.
Maintenance
3
Visually inspect the exterior housing of the laser to ensure that all warning labels are present. Refer
to Firestar ti-Series label locations in the Laser Safety chapter for label types and locations.
Storage/shipping
When preparing a water-cooled laser for storage or shipping, remember to drain cooling water from the
laser. In cold climates any water left in the cooling system may freeze, which could damage internal
components. After draining thoroughly, use compressed shop air at less than 29 PSI (while wearing safety
glasses!) to remove any residual water. When finished, cap all cooling connectors to prevent debris from
entering the cooling system.
When shipping SYNRAD lasers to another facility, we highly recommend that you ship the unit in its
original SYNRAD shipping container. If you no longer have the original shipping box and inserts, contact
SYNRAD Customer Service about purchasing replacement packaging. Refer to Firestar ti-Series packaging
instructions in the Technical Reference chapter for detailed instructions on packaging the laser for ship-
ment.
Important Note: Failure to properly package the laser using a SYNRAD-supplied shipping box and
foam/cardboard inserts as shown in the Packaging Instructions may void the war-
ranty. Customers may incur additional repair charges due to shipping damage caused
by improper packaging.
Cleaning optical components

Table of Contents

Other manuals for Synrad Firestar TI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Synrad Firestar TI Series and is the answer not in the manual?

Synrad Firestar TI Series Specifications

General IconGeneral
BrandSynrad
ModelFirestar TI Series
CategoryMedical Equipment
LanguageEnglish

Related product manuals