troubleshooting
410
Synrad Firestar ti-Series operator’s manual
Troubleshooting
Table 4-3 Interlock Open condition
LED Indicator LED Status Signal Name Output Signal Status
INT Red Interlock Open Closed
TMP Green Over Temperature Open
RDY Off Laser Ready Open
SHT Blue Shutter Open Closed
LASE Off Laser Active Open
Table 4-4 Over Temperature condition
LED Indicator LED Status Signal Name Output Signal Status
INT Green Interlock Open Open
TMP Red Over Temperature Closed
RDY Off Laser Ready Open
SHT Blue Shutter Open Closed
LASE Off Laser Active Open
Table 4-5 Shutter Open condition
LED Indicator LED Status Signal Name Output Signal Status
INT Green Interlock Open Open
TMP Green Over Temperature Open
RDY Yellow Laser Ready Closed
SHT Off Shutter Open Open
LASE Off Laser Active Open