Do you have a question about the Taie FU96 and is the answer not in the manual?
Safety warnings for electrical shock and proper usage.
Precautions for installation and power supply to avoid damage.
Detailed wiring diagram for FY400/FU400/FU48 controller terminals.
Detailed wiring diagram for FY600 controller terminals.
Detailed wiring diagram for FY700/FU72 controller terminals.
Detailed wiring diagram for FY800/FU86 controller terminals.
Detailed wiring diagram for FY900/FU96 controller terminals.
Steps to perform automatic tuning for optimal PID control parameters.
How to manually set or adjust PID control parameters.
Monitors heater current and triggers an alarm if a disconnection or abnormality occurs.
Describes how the controller manages motor valve operations with or without feedback.
Enables setting temperature profiles with timed ramps and soak periods.
Explains the various alarm modes available for system protection and application needs.
Details parameters for program pattern selection, segment settings, and output limits.
Configuration for program time format, start address, repeat, and power failure protection.
Step-by-step guide for creating and defining program patterns and segments.
Flowchart for calibrating the 4~20mA output signal.
Step-by-step guide for calibrating CLO1 and CHO1 for output signals.
Detailed steps for calibrating linear input signals, including ANL1 and ANH1.
Safety warnings for electrical shock and proper usage.
Precautions for installation and power supply to avoid damage.
Detailed wiring diagram for FY400/FU400/FU48 controller terminals.
Detailed wiring diagram for FY600 controller terminals.
Detailed wiring diagram for FY700/FU72 controller terminals.
Detailed wiring diagram for FY800/FU86 controller terminals.
Detailed wiring diagram for FY900/FU96 controller terminals.
Steps to perform automatic tuning for optimal PID control parameters.
How to manually set or adjust PID control parameters.
Monitors heater current and triggers an alarm if a disconnection or abnormality occurs.
Describes how the controller manages motor valve operations with or without feedback.
Enables setting temperature profiles with timed ramps and soak periods.
Explains the various alarm modes available for system protection and application needs.
Details parameters for program pattern selection, segment settings, and output limits.
Configuration for program time format, start address, repeat, and power failure protection.
Step-by-step guide for creating and defining program patterns and segments.
Flowchart for calibrating the 4~20mA output signal.
Step-by-step guide for calibrating CLO1 and CHO1 for output signals.
Detailed steps for calibrating linear input signals, including ANL1 and ANH1.
| Brand | Taie |
|---|---|
| Model | FU96 |
| Category | Controller |
| Language | English |