M8SL2-00-002-812 General Information F1.3
© Copyright Tait Electronics Limited August 2004. All rights reserved.
Power Factor at full load:
230V
AC
supply … >0.96
115V
AC
supply … >0.98
Note: Exact power factor depends on impedance of mains supply.
Input Fuse (Internal) … 5A 250V fast acting
(Littlefuse 217 series)
1.2.4 Output
Output Voltage … 13.8V
DC
Note: A drop of up to 0.5V may be expected across the wiring from the power sup-
ply to the load.
Vol t ag e R eg u la t i o n … ±0.5%
Current
Operation from 200–240V
AC
supply:
Continuous, –10°C to +50°C … 0 to 14.5A
DC
Continuous, up to +60°C … 0 to 8.5A
DC
Operation from 100–130V
AC
supply:
Continuous, –10°C to +20°C … 0 to 14.5A
DC
Continuous, +20°C to +50°C … 0 to 8.5A
DC
Note: Continuous operation from 115V
AC
supplies in ambient temperatures
exceeding +50°C is not recommended, as this will cause the equipment to
overheat.
Output Overvoltage Protection … 14.8 to 19.1V
DC
Type: Shu tdown
Reset: Power off and on
Output Hum and Noise … <100mV
pp
(At full load, with mains supply volt-
age = 230V)
Current Overload Limit … 15.2 to 21.8A
Type: Constant current limiting
Reset: Auto recovery
Output Connector … Molex 6-way receptacle
Note: Refer to Figure 3.1 in Section 3.2 for the output connector pinouts.