C3.20 T854 Initial Tuning and Adjustment M8SL2-00-002-812
© Copyright Tait Electronics Limited August 2004. All rights reserved.
Remove and fit the following resistors:
4. Double-sided tape is attached to the bottom side of the plug-in board. Remove the
protective film from the double-sided tape to expose its adhesive surface.
5. The plug-in board is mounted in the T854 microcontroller cavity. Plug J1, the con-
nector on the bottom side of the plug-in board, into SK805 on the T854 main
board.
6. Firmly press down on the edges of the plug-in board so that the double sided tape
bonds to the top of the microcontroller.
7. Connect the ribbon-cable between J2 on the plug-in board, and the auxiliary
D-Range board.
3.10.2.2 T800-10-0520 Testing/Alignment
Equipment required
50 power meter
Suitable attenuator, e.g. 3dB.
Forward alarm
1. Connect the power meter to the transmitter output.
2. Key up the transmitter and set the output power to the desired low forward-
power alarm threshold-point.
3. Adjust RV2, the forward-power alarm preset, until the forward alarm LED (DS2)
just turns ON.
3B: Fit %R308 and %R310 in
the exciter cavity. Use 10k
SMD0805 (IPN: 036-15100-10).
3A: Remove R841 and R840
from the microcontroller cavity.
Fit the plug-in
board into the
microcontroller
cavity.

Table of Contents