T-K3 Service Manual
Ver. 1.05
13
CONFI DENTIAL
10-1. Burners
T-K3 Part # #101 Takagi Part # EKK1 N Checkpoint N/A
Function
F ailure events
Effects on the T-K3
if burners fails
Error codes when the
burners fail
D iagnostic
Color/Number of
wires
N/A
Visual inspection: excessive dust deposit on the burner surface and/or unstable
flame conditions durin g o pe ration.
There are 2 types of burners in the T-K3: the gas-rich burner stabilizes the flames
within the combustion chamber and the air-rich burner produces more heat in the
combustion chamber. The burners facilitate the air/gas mixture necessary to
pr od uce the proper heat during the com bustion reaction.
1. Unable to initialize/sustain combustion
2. Dust or soot deposit on the burner surface.
3. Cracks on the burners. 4. Gas leakage from burners
1. An un expecte d combustion.
2. Unstabl e flam e conditions an d/o r flame loss.
3. Ignition failure.
111 121
3-1/8 " (80mm)
5-5/8" (143.2mm)
6-3/4" (170mm)
3 /8" (11.0mm)
Si xt ee n T- K3 B ur ne rs
T- K3 B ur ne r