EasyManua.ls Logo

Takagi T-K3 - Page 39

Takagi T-K3
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T-K3 Service Manual
Ver. 1.05
39
CONFI DENTIAL
Checkpoint
1
2 Check for signs of power surges.
Abnormal burning
(Refer to section 12-3)
Checkpoint
1 Check for blockage on the air inlet of the T-K3.
2 Check for blockage of the exhaust run.
3 Check for
p
ro
p
er manifold
p
ressure in the T-K3.
4
761
Consider altitude/elevation of region of where the T-K3
installed.
991
Error Code Malfunction description Cancellation method
Miscommunication between Master and
Slave units for Easy-Link systems.
Restoring proper cable
connections among all the T-K3s.
When the computer detects
proper connections among all the
T-K3s, "761" error code will
cease to display.
Diagnosis
Inspect cable connections between Master and Slave units.
Dia
g
nosis
Error Code Malfunction description Cancellation method
Turn off the power or water
supply
If not possible, press and hold
the INC and DEC buttons on the
computer board simultaneously
for more than 3 sec.

Table of Contents

Other manuals for Takagi T-K3

Related product manuals