132
TROUBLESHOOTING
Other Symptoms
For symptoms not included on the table below or if the problem persists after the proper
procedures have been taken, consult a Takeuchi sales or service outlet.
Symptom Main cause Procedure
¡ Safety lock lever is raisedHoe attachment,
slewing or traveling
operation not possible
¡ Lower the safety lock lever.
Refer to page 43.
Digging force is
insufficient
¡ Insufficient hydraulic oil level
¡ Hydraulic oil is not heated
¡ Air cleaner is clogged
¡ Hydraulic oil is not of
suitable type
¡ Replenish to the prescribed
level.
Refer to page 100.
¡ Perform the warm-up
procedure.
Refer to page 58.
¡ Clean the air cleaner.
Refer to page 111.
¡ Replace the hydraulic oil.
Refer to page 117.
Traveling is not
possible or not smooth
¡ Stones or foreign objects are
stuck
¡ Remove the foreign object.
Machine does not travel
straight forward
¡ Stones or foreign objects are
stuck
¡ Faulty crawler tension
adjustment
¡ Remove the foreign object.
¡ Adjust the crawler to the
prescribed tension.
Refer to page 105.
Slewing is not possible
or not smooth
¡ Insufficient grease on slew
bearing
¡Add grease.
Refer to page 106.