✔✔ <ESC>a<n> select justification and centering mode
<n> = 0 ➵ left justification
1 ➵ centered
2 ➵ right justification
3 ➵ left and right justification
✔✔<ESC>A<n> Set line feed to n/60 inch (<n> = 1 - 127)
✔✔✔ <ESC>A<n> Set n/72 inch line feed (<n> = 1 - 85)
✔✔ <ESC>b<m><0> clear all tab settings
✔✔ <ESC>b<m><n><0> set vertical tabs in channels <m> = 0 - 3
<n> = 1 - 154
✔✔✔✔ <ESC>B<0> reset all vertical tab stops
✔✔ <ESC>B<n1>..<n16><0> set vertical tab stops
✔✔ <ESC>B<n1>..<n64><0> set vertical tab stops
✔✔✔✔ <ESC>C<0><n> set form length in inches (<n> = 1 - 22)
✔✔✔✔ <ESC>C<n> set form length in lines (<n> = 1 - 127)
✔ <ESC>d<n1><n2> set relative horizontal step
Formula: n = relative print position
<n2> = INT (n/256)
<n1> = n MOD 256
✔✔✔✔ <ESC>D<0> clear all horizontal tab stops
✔✔✔✔ <ESC>D<n1>..<n32><0> set horizontal tab stops
✔✔✔✔ <ESC>E emphasized mode ON
✔✔✔✔ <ESC>F emphasized mode OFF
✔ <ESC>g set character density to 15 cpi
✔✔✔ <ESC>G double strike print mode ON
✔ <ESC>G print quality NLQ ON
✔ <ESC>H print quality NLQ OFF
✔✔✔ <ESC>H reset double strike print mode
✔ <ESC>I<1> characters 0 - 31 and 128 - 159 transparent
✔ <ESC>I<0> downloaded or international characters
✔✔ <ESC>I<n> print mode selection
<n>
0 DPQ DPQ 10 cpi
1 DPQ –
2 NLQ NLQ/LQ 10 cpi
3 NLQ NLQ/LQ Prop.
4 DPQ (DLL) DPQ 10 cpi (DLL)
5 DPQ (DLL) –
6 NLQ (DLL) NLQ/LQ 10 cpi (DLL)
7 NLQ (DLL) NLQ/LQ Prop. (DLL)
8 – DPQ 12 cpi
10 – NLQ/LQ 12 cpi
IBM IBM Epson Epson IBM-
MTPL Propr. Propr. FX850 LQ850+ AGM Code Function
X/XL X24/XL24 FX1050 LQ1050+
List of available control codes
2 - 12