87
Model C606 Operating Procedures
Step 12
Install the cylinder onto the larger opening in the
valve body by tilting the cylinder away from the
discharge tube and sliding the widest section of
flange under the center locking groove on the valve
body. Align the tabs on the cylinder with the locking
grooves on the valve body. Turn the cylinder
clockwise until the tabs fully engage into the locking
grooves on the valve body.
Step 13
Install the lid by inserting the discharge tube through
the smaller hole in the lid. Slide the lid until the
larger hole fits around the top of the cylinder. The
discharge tube lock nut will secure the lid in position.
Step 14
Install the discharge tube lock nut. Tighten the lock
nut by turning it clockwise.
Step 15
Lubricate and install the plunger assembly into the
cylinder opening in the pump body.
(See Figure 222.)
Figure 222
Step 16
Tighten the plunger nut by turning it clockwise.
(See Figure 223.)
Figure 223
Manual Brush Cleaning
This Procedure Must Be Completed Every Two
Weeks!
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble the Model C606, the following items
will be needed:
S Two cleaning and sanitizing pails for each
side of the freezer
S Necessary brushes (provided with freezer)
S Cleaning solution
S Sanitizing solution
S Single service towels
S Parts trays